The Single-cell QA/QC task in Partek Flow enables you to visualize several useful metrics that will help you include only high-quality cells. To invoke the Single-cell QA/QC task: 

  • Click a Single cell counts data node
  • Click the QA/QC section of the task menu
  • Click Single cell QA/QC


If your Single cell counts data node has been annotated with a gene/transcript annotation, the task will run without a task configuration dialog. However, if you imported a single cell counts matrix without specifying a gene/transcript annotation file, you will be prompted to choose the genome assembly and annotation file by the Single cell QA/QC configuration dialog (Figure 1). Note, it is still possible to run the task without specifying an annotation file. If you choose not to specify an annotation file, the detection of mitochondrial counts will not be possible.


Figure 1. If an annotation was not specified on import, you can choose the assembly and annotation after invoking Single-cell QA/QC

The Single cell QA/QC task report opens in a new data viewer session. Four dot and violin plots showing the value of every cell in the project are displayed on the canvas: counts per cell, detected features per cell, the percentage of mitochondrial counts per cell, and the percentage of ribosomal counts per cell (Figure 2).


Figure 2. Dot & violin plots showing values of each cell for several quality measures

If your cells do not express any mitochondrial genes or an appropriate annotation file was not specified, the plot for the percentage of mitochondrial counts per cell will be non-informative (Figure 3).


Figure 3. A non-informative percentage of mitochondrial counts plot
Mitochondrial genes are defined as genes located on a mitochondrial chromosome in the gene annotation file. The mitochondrial chromosome is identified in the gene annotation file by having "M" or "MT" in its chromosome name. If the gene annotation file does not follow this naming convention for the mitochondrial chromosome, Partek Flow will not be able to identify any mitochondrial genes. If your single cell RNA-Seq data was processed in another program and the count matrix was imported into Partek Flow, be sure that the annotation field that matches your feature IDs was chosen during import; Partek Flow will be unable to identify any mitochondrial genes if the gene symbols in the imported single cell data and the chosen gene/feature annotation do not match. 

Ribosomal genes are defined as genes that code for proteins in the large and small ribosomal subunits. Ribosomal genes are identified by searching their gene symbol against a list of 89 L & S ribosomal genes taken from HGNC. The search is case-insensitive and includes all known gene name aliases from HGNC. Identifying ribosomal genes is performed independent of the gene annotation file specified.

Total counts are calculated as the sum of the counts for all features in each cell from the input data node. The number of detected features is calculated as the number of features in each cell with greater than zero counts. The percentage of mitochondrial counts is calculated as the sum of counts for known mitochondrial genes divided by the sum of counts for all features and multiplied by 100. The percentage of ribosomal counts are calculated as the sum of counts for known ribosomal genes divided by the sum of counts for all features and multiplied by 100.

Each point on the plots is a cell. All cells from all samples are shown on the plots. The overlaid violins illustrate the distribution of cell values for the y-axis metric. 

The appearance of a plot can be configured by selecting a plot and adjusting the settings in the Configuration cards on the left (Figure 4). Here are some suggestions, but feel free to explore the other options available:

  • Open the Color card and reduce the Opacity using the slider. For data sets with very many cells, it may be helpful to decrease the dot opacity to better visualize the plot density.
  • Open the Scale card and change the Y-axis scale to Logarithmic. This can be helpful to view the range of values better.
  • Open the Summary card and switch on Box & Whiskers. Inspecting the median, Q1, Q3, upper 90%, and lower 10% quantiles of the distributions can be helpful in deciding appropriate thresholds.


Figure 4. Use the Configuration cards on the left customize the appearance of plots
High-quality cells can be selected using the Selection card on the right, which is pre-loaded with three selection rules, one for each quality metric (Figure 5).


Figure 5. The Selection card with three selection rules
Hovering the mouse over one of the selection rules reveals a histogram showing you the frequency distribution of the respective quality metric. The minimum and maximum thresholds can be adjusted by clicking and dragging the sliders (Figure 6).


Figure 6. Use the sliders and histograms to adjust the selection criteria
Alternatively, the thresholds can be set by typing directly into the text boxes in each selection rule (Figure 7).


Figure 7. Minimum and maximum thresholds can be set by manually typing into the text boxes
Adjusting the selection criteria will select and deselect cells in all three plots simultaneously. Depending on your settings, the deselected points will either be dimmed or gray. The filters are additive. Combining multiple filters will include the intersection of the three filters. The number of cells selected is shown in the figure legend of each plot (Figure 8).


Figure 8. The figure legends show 3696/4352 cells with total count <12,000, number of detected features 600 - 2500, and % mitochondrial count <5% are selected in all three plots. Selected cells are blue, deselected cells are dimmed.
To filter the high-quality cells, click the  icon in the Filtering card in the top right, and click Apply filter... (Figure 9).


Figure 9. Include the selected points and apply the filter
Select the input data node for the filtering task and click Select (Figure 10).


Figure 10. After the Apply filter button is selected, you will be presented with a preview of your pipeline. You need to select the appropriate data node to apply the filtering to
A new data node, Filtered counts, will be generated under the Analyses tab (Figure 11).


Figure 11. Filter cells task runs from the Single cell QA/QC report


Additional Assistance