Section Heading

Section headings should use level 2 heading, while the content of the section should use paragraph (which is the default). You can choose the style in the first dropdown in toolbar.

 

 The Violin plot in Partek Genomics Suite is similar to the Profile Trellis plot in that it displays probe(set)/gene intensity values across samples and genes. However, the Violin plot has additional options not shared by the Profile Trellis plot. Here, we will explore one use case for the Violin plot. 

Displaying intensity value ranges for multiple genes grouped by categorical variables

For this example, we will use the data set and lists created in the Gene Expression tutorial. We have a list of 23 genes that are differentially regulated in tissue samples from patients with Down syndrome and normal controls. We want to display the mean intensity values for Down syndrome and normal samples for each of the 23 genes on a single plot. To do this, we first need to filter the probe intensities spreadsheet to include only the intensity values for the 23 genes of interest. 

With the probe intensities spreadsheet and the gene list open in the Analysis tab, follow these steps to filter the probe intensities spreadsheet. 

  • Select the probe intensities spreadsheet in the spreadsheet tree; here, it is Down_Syndrome-GE
  • Select Filter from the main task bar
  • Select Filter Columns
  • Select Filter Columns Base on a List... (Figure 1)

 

Numbered figure captions
SubtitleTextInvoking filter columns by a list
AnchorNameInvoking filter columns

Image Added

The Filter Columns dialog will open (Figure 2). 

 

Numbered figure captions
SubtitleTextConfiguring the Filter Columns dialog to filter by probe set ID
AnchorNameConfiguring filtering

Image Added

  • Select your gene list from the Filter base on spreadsheet drop-down menu; here, we selected Down_Syndrome_vs._Normal
  • Select the column of your gene list that matches the column IDs you want to filter from your probe intensities spreadsheet; here, we selected 2. Probeset ID
  • Select OK to apply the filter

A black and yellow horizontal bar will appear at the bottom of the spreadsheet. This is the filter indicator showing the proportion of columns (genes/probesets) filtered out (black) and retained (yellow). To continue working with the filtered probeset intensities, we can clone the filtered spreadsheet.

  • Right-click on the filtered probe intensities spreadsheet in the spreadsheet tree
  • Select Clone... from the pop-up menu (Figure 3)

Numbered figure captions
SubtitleTextCloning a spreadsheet with a filter applied will clone only the retained rows/columns
AnchorNameCloning filtered spreadsheet

Image Added

  • Name the new spreadsheet; we chosen 2
  • Select OK

The cloned spreadsheet is a temporary file. To ensure we can use it again if we close Partek Genomics Suite, we should save the filtered probe intensities spreadsheet. 

  • Select (Image Added)
  • Name the new file; we chose Down_Syndrome_vs_Normal_Probe_Intensities

Now we have a spreadsheet containing only the probe intensity values for our 23 genes of interest (Figure 4).

 

Numbered figure captions
SubtitleTextFiltered probe intensities spreadsheet
AnchorNameFiltered probe intensities spreadsheet

Image Added

We can now invoke the Violin plot. Make sure to have the filtered probe intensities spreadsheet selected (in blue) in the spreadsheet tree as shown (Figure 4).  

  • Select View from the main taskbar 
  • Select Violin Plot from the menu

Violin Plot tab will open (Figure 5). This plot shows the intensity value ranges of the 23 genes (probe sets) for all samples as violin plots.

 

Numbered figure captions
SubtitleTextViewing violin plots for 23 genes
AnchorNameViolin Plots

Image Added 

  • Select View from the main taskbar
  • Select Toggle Properties

We can now see the plot properties panel to the left of the violin plot (Figure 6). 

 

Numbered figure captions
SubtitleTextThe violin plot can be configured using the plot properties panel
AnchorNameConfiguring Violin Plot

Image Added

Although it is called the Violin plot, this visualization can also be used to display box and whisker plots, error bar plots, and gradiant plots. For this example, we will generate box and whisker plots, summarized by Type (Down syndrome and normal), for each gene. 

  • Select Box and Whisker Plot from the Plot type drop-down menu
  • Select Type from the Summarize by drop-down menu; this can be any categorical variable
  • Select Hide legend from Legend Options
  • Select Apply to modify the plot

The modified plot shows box and whisker plots, Down syndrome samples in red and normal in blue, for each gene (Figure 7). 

 

Numbered figure captions
SubtitleTextViewing average probe intensity values for two groups across 23 genes as box and whisker plots
AnchorNameBox and Whisker plot

Image Added

To improve our view of the gene symbols, we can modify the X-axis legend. 

  • Select X-Axis from the tabs in the plot properties panel
  • Set Text angle to 90 under Labels
  • Uncheck Trucate labels under Labels
  • Uncheck Show Outline under Blocks
  • Uncheck Columns under Attributes 
  • Select Apply (Figure 8)

 

Numbered figure captions
SubtitleTextConfiguring the X-axis label
AnchorNameConfiguring x-axis

Image Added

The gene symbol for each column should now be visilble (Figure 9). In cases where probe intensities for your genes of interest fall across a wide range, it may be helpful to normalize the probe intensity distributions of each gene. This is equivalent to what is done to display a heat map of probe intensity values. 

 

Numbered figure captions
SubtitleTextX-axis now labels with gene symbols for each gene
AnchorNameModified x-axis

 Image Added

  • Select the Style tab
  • Select Standardize - shift column to mean of zero and scale to standard deviation of one from the Normalization options
  • Select Apply 

The box and whisker plots are now centered with a mean of zero and scaled to have a standard deviation of one (Figure 10). Similar to a heat map, this makes it easier to visualize which genes are upregulated and which are downregulated. Here, we can see that most of the 23 genes are expressed more highly in Down symdrome patients.

 

Numbered figure captions
SubtitleTextViewing normalized box and whisker plots
AnchorNameNormalized box and whisker plots

Image Added

Plots can also be split by categorical variables. We can use this to visualize differential expression of genes between Down syndrom and normal patients in different tissue types. 

  • Select Configure profile 
  • Select Switch to Advanced (Figure 11)

Numbered figure captions
SubtitleTextSimple options for configuring profiles in the plot
AnchorNameConfigure profile dialog

Image Added

  • Select Sub-Plot for Tissue (Figure 12)

 

Numbered figure captions
SubtitleTextConfiguring plot properties to split by Tissue
AnchorNameConfiguring Advanced Properties

 Image Added

  • Select OK 

Several options will need to be reconfigured before we apply this change.

  • Select Standardize - shift column to mean of zero and scale to standard deviation of one from the Normalization section 
  • Select the X-axis tab
  • Set Text Angle to 90
  • Deselect Truncate labels 
  • Deselect Show outline
  • Deselect Columns 
  • Select Apply

There should now be a sub-plot for each category, in this case there are four sub-plots, one for each tissue (Figure 13). There are no error bars for several plots because there are not enough samples in those categories. 

 

Numbered figure captions
SubtitleTextSplitting a plot by a categorical factor, Tissue, and grouping by another categorical variable, Type
AnchorNameSplitting plots

Image Added

These sub-plots can be displayed all together, or individually. 

  • Select from the Items/Page drop-down menu

You can now move through the sub-plots by selecting Next >

  • Select All from the Items/Page drop-down menu to return to the 2x2 view

This data can also be displayed as a gradient plot (Figure 14) or error bar plot (Figure 15) by changing the Plot type using the drop-down menu in the Style tab. By default, the shading range in the gradiant plot and the error bars show +/-1 standard deviation from the mean. 

 

Numbered figure captions
SubtitleTextGradient plot
AnchorNameGradient plot

Image Added

Numbered figure captions
SubtitleTextError bar plot
AnchorNameError bar plot

Image Added

The final option, violin plot, cannot be used to display samples grouped by a categorical variable. To view a violin plot, we must remove the Summarize by selection. 

  • Select (One profile per sub-plot) from the Summarize by drop-down menu
  • Select Violin plot from the Plot type drop-down menu
  • Select None - do not adjust values for Normalization
  • Select Apply

The plot now displays violin plots for each gene showing the distribution of probe intensity values for each tissue in a separate sub-plot (Figure 16).

 

Numbered figure captions
SubtitleTextViolin plots for each gene, sub-plots for each tissue
AnchorNameViolin plots

Image Added

 



Additional assistance

 

Rate Macro