Space Ranger 1.3.0 has been wrapped in Partek Flow as Space Ranger task. It does not include all the options and uses cases covered by Space Ranger, but The task takes .fastq and .jpeg/.tiff files as input and performs alignment, filtering, barcode counting, and UMI counting. The output is gene expression count matrix in a .h5 format (both raw and filtered are available for download via Task Details), which then becomes the starting point for downstream analysis in Partek Flowas well as a .zip file with spatial files (image). Note that the Space Ranger task in Partek Flow does not include all the options and uses cases covered by the Space Ranger pipelines of 10x Genomics.

Running Space Ranger in Partek Flow

...

Numbered figure captions
SubtitleTextDownloading a Cell Ranger reference. Supported references appear in the drop down menu
AnchorNamedownload_cell_ranger_reference

Image Modified


Downloading a reference is a separate task and may take some time. However, it the reference will become immediately available in the Cell Ranger 6.0.0. reference drop down (Figure 4).

...

The sample table under Input options has one row per sample (Figure 2). Image file is required, and that is a single hematoxylin and eosin brightfield image in either .jpg or .tiff format. Click on the Browse button under Browse image file and the file browser will come up. Point to the image file and push Continue. Probe set file is optional; it is a .csv file specifying the probe set used (=target panel).

If you want to specify sample's slide and area information, tick mark the box by the Use slide serial number file and then click Browse to point to the file. The file should be tab-delimited with samples on rows. The first column is the sample name, slide name is on the second column, slide area on the third column.

Click on the Configure link in the Advanced options section to open the Advanced options dialog (Figure 5). Use R1 length to hard trim the R1 reads to specified length; use R2 length to hard trim the R2 reads to specified length. Use the Memory limit option to cap the RAM usage (in GB).

...

The result of Space Ranger task is the Single cell counts data node, which contains the gene expression data. Double click the Single cell counts node to invoke the report the task report (Figure 6) which is the same as the ‘Summary HTML’ from Space Ranger outputthe original 10x Genomic pipelines. Task report is sample based. You can use the dropdown list in top left to switch samples (not shown in Figure 6).  Each report consists of two pages: Summary and Analysis. For deatails, please visit 10x Genomics web page.

...

Numbered figure captions
SubtitleTextData Viewer session as a result of opening an Annotated counts data node. Each data point is a tissue spot
AnchorNamedata_viewer_annotated_counts

...